当前位置: 首页 行业新闻 内置可以适当调节系统流量的静态平衡阀

行业新闻

原文:
The origin of modern to warm in North America and Europe, then in Japan, Korea and other countries more widely used and developed. Into the 21st century, with floor heating technology continues to progress and the development and application of new materials, to promote rapid warm. Warm, as aButterfly Valves scientific art heating system, its superior quality has been accepted and recognized by many consumers, the Beijing Olympic venues in one fell swoop the main heating, offers the highest technology to ensure the Olympic venues, green, environmental protection, energy saving architectural requirements. Option 1 - Standard type Built-in adjustment-type sub-catchment, artificial regulator manifolds loop flow balance, the catchment can be regional control, and ground loop to open and warm relations. Recommended theInstrumentation Ball Valves reservation of control cable and power cord, easy to install in future electric actuator, thermostat upgrade household or sub-room temperature control. Catchment device: heat pipe to connect separate ways back to the mains water catchment devices, built-in control valve can be manually turned on or off to warm the slip road. Manifold: to connect separate ways heating pipe water pipes waterCheck Valves distribution installations, built-in flow conditioning systems can be appropriate for static balancing valves. The same radiant floor heating system in several different lengths of radiant floor heating with water pipes, water pipes must be based on pressure drop for return to pre-regulate the flow pipe. This helps balance the various circuits. Construction Note: sub-catchment device body and the body, and the end of the connection. Programme 2 - household temperature control system On the basis of the standard addition of a thermostat and an electric valve (or electric valve), the boiler thermostat control linkage with the output. When the room temperature reaches the set comfort temperature, electric valves automatically close, or you can make the boiler to stop working. Under the premise of ensuring a comfortable, automated control and energy saving operation. Electric household temperature control valve body part, and with electric actuator for closed loop water system. And actuator SEA ... or SEH ... connection, automatic control of fluid regulation. Programme 3 - compartment temperature control system Typical "sub-room temperature control," self-control system to warm theSafety Valves program, is the room for the regional unit, to achieve an independent sub-room temperature control system; the use of each room are different in nature, you can set different temperatures. Reasonable distribution of heat, reduce heat waste, can achieve real "comfortable and energy-saving" purposes. Catchment control valve device installed electric actuator, actuator installed in the region by the room thermostat control. Each room's temperature can be set for the room temperature. If circulation pump, gas wall-hung boilers, control box can be set for system control linkage. Sub-room temperature the central controller, referred to as centralized control (line) box. Used in intelligent control system for floor heating, warm water systems in the catchment would be to slip the electronic control devices valve together with the room temperature controller connected to theBalance Valves central control processing. System, heat source wall-hung boilers, pressurized circulating pump control linkage can be realized. Centralized control box with cable, wireless two, this article is to introduce a wired way. Set wireless multi-channel junction box, especially for system upgrades.
原文来自:http://www.nytimes.com/1996/02/16/nyregion/new-jersey-daily-briefing-valve-caused-pipes-to-burst.html

NEW JERSEY DAILY BRIEFING;Valve Caused Pipes to Burst;是由 上海赛泰泵阀有限公司提供的阀门新闻,中文译文仅供参考,以下提供站内导航搜索:

中国球阀网 球阀产品 球阀知识 球阀厂商 球阀论坛 球阀行业新闻


以下是参考译文:

译文:内置可以适当调节系统流量的静态平衡阀
现代地暖起源于北美和欧洲,进而在日本、韩国等国家得到深井泵 更广泛的应用和发展。进入21世纪,随着地暖技术的不断进步和各种新材料的开发应用,地暖得到快速推广。地暖,作为一种科学先进的供暖系统,其卓越的品质已经被众多消费者接受和认可,一举成为北京奥运场馆的主要供暖方式,最大程度保证了奥运场馆科技、绿色、环保、节能的建筑要求。 方案1--标准型 内置式调节型分集水器,人工调节分水器回路流量平衡,集水器可分区控制,对离心泵 地暖回路进行开与关。建议预留控制线缆与电源线,便于日后加装电热执行器、温控器升级为分户或分室恒温控制。 集水器:连接各路加热管回水管的汇水装置,内置调节阀可以手动开启或关闭地暖各支路。 分水器:连接各路加热管供水管的配水装置,内置可以适当调节系统流量的静态平衡阀。同一地板辐射采暖设施中有多个不同长度的地板辐射采暖配水管,必须根据供回水管的压降来预调节管路的流量。这样有助于平衡各个回路。施工过程注意事项:分集水器体与体,与末端的连接。 方案2--分户控温系统 在标准型的基础上增加一个温控器与一个电动阀(或电热阀),温控器备有控制锅炉的联动输出。当管道泵 房间温度达到设定的舒适温度时,电动阀自动关闭、也可以使锅炉停止工作。在确保舒适的前提下,实现自动化控制与节能运行。 分户恒温控制电动阀的阀体部分,与电动执行器配合,适用于闭式循环水系统。与执行器SEA...或SEH...连接,对流体自动控制调节。 方案3--分室控温系统 典型的“分室控温”地暖自控系统方案,是以房间为区域单元,实现分室的独立恒温控制系统;根据螺杆泵 每个房间的使用性质不同,可以设置不同的温度。合理分配热源,减少热源浪费,能达到真正的“既舒适又节能”的目的。 集水器的控制阀门加装电热执行器,执行器由安装在各区域的房间温控器控制。每个房间的温控可以独立设置房间温度。如有循环泵、燃气壁挂炉,可由集控盒进行系统联动控制。 分室恒温中央控制器,可简称为集控(线)盒。应用于智能型地暖控制系统,将隔膜泵 地暖水系统中集水器的支路的电控阀门与各房间温控器汇集连接,进行中央控制处理。系统的热源壁挂炉、增压循环水泵可实现联动控制。集控盒有有线、无线两种,本文是介绍的是有线的方式。无线磁力泵 多通道集线盒,特别适合系统升级。

更多新闻

  • 河道修了水闸重新修补管道阀
  • 擅自关闭了供水阀门,打算私自进行管线连接
  • 供核电站用的阀门大多是非核级和核Ⅱ、Ⅲ级阀门
  • 成交量回暖的“阀门交易量